Cornick Help Center

    One Key Config with G Series Intercoms

    August 27th, 2020

    1 Door Station & 1 Indoor Monitor

    This method requires the least amount of time to setup and does not require a computer. However, a computer will be required to adjust settings such as door latch timing and date & time.

    Below are the example details that we will be using for this guide. If you intend on connecting the intercom to your network for remote access, you will need to obtain the local IP address details for your network. (Refer to this article.) Replace the example IP addresses with IP addresses suitable for your network.

    Device IP Address Subnet Mask Gateway Password Type Main/Sub
    Door Station 192.168.1.108 255.255.255.0
    192.168.1.1 admin123 VTO Main
    Indoor Monitor 192.168.1.109 255.255.255.0
    192.168.1.1
    888888 VTH Main

    1. Connect the intercom equipment.

    2. Go to the Indoor Monitor, all configuration will be performed from this device. If prompted to select a language, select English, then select OK. If not prompted, proceed to the next step.

    3. If prompted to choose Apartment or Villa, select Villa, then select OK. If not prompted, proceed to the next step.

    4. Initialize the Indoor Monitor, by entering a 6 digit password (888888) and email. Select OK.

    5. If prompted with Do you want to do quick configuration?, Select OK. If Step 3 was completed, skip this step. 

    6. Select Initialize next to the uninitialized Door Station (VTO) and set a user password (admin123) and email. Select OK

    7. Once all of the devices are initialized, select Next.

    8. Select Edit next to the Indoor Monitor (VTH). Set the device type to Main and set the IP Address (192.168.1.109), Netmask (255.255.255.0) and Gateway (192.168.1.1). Select OK. 

    9. Select Edit next to the Door Station (VTO). Set the device type to Main and set the IP Address (192.168.1.108), Netmask (255.255.255.0) and Gateway (192.168.1.1).  Set the Time and Date. Select OK.

    10. Once all devices have had their IP address details and device type set, select One-Key Config. The devices will now be configured. NOTE: If an error occurs during the configuration, ensure the entered details are correct.

    11. Once the devices have successfully configured, select OK

    12. The devices will reboot, allow up to 10 minutes for them to connect. 

    2 Door Stations, 2 Indoor Monitors


    This method requires the least amount of time to setup and does not require a computer. However, a computer will be required to adjust settings such as door latch timing and date & time.

    Below are the example details that we will be using for this guide. If you intend on connecting the intercom to your network for remote access, you will need to obtain the local IP address details for your network. (Refer to this article.) Replace the example IP addresses with IP addresses suitable for your network.

    Device IP Addresses Subnet Mask Gateway Password Type Main/Sub
    Door Station 1 192.168.1.108 255.255.255.0
    192.168.1.1 admin123 VTO Main
    Door Station 2 192.168.1.111 255.255.255.0
    192.168.1.1
    admin123 VTO Sub
    Indoor Monitor 1 192.168.1.112 255.255.255.0
    192.168.1.1
    888888 VTH Main
    Indoor Monitor 2 192.168.1.113 255.255.255.0 192.168.1.1
    888888 VTH Sub

    1. Connect the intercom equipment

    2. Go to the Indoor Monitor which will be your Master Indoor Monitor, all configuration will be performed from this device, do not configure any other monitor. If prompted to select a language, select English, then select OK. If not prompted, proceed to the next step.


    3. If prompted to choose Apartment or Villa, select Villa, then select OK. If not prompted, proceed to the next step.

    4. Initialize the Indoor Monitor, by entering a 6 digit password (888888) and email. Select OK.


    5. If prompted with Do you want to do quick configuration?, Select OK. If Step 3 was completed, skip this step.

    6. Select Initialize next to the second uninitialized Indoor Monitor (VTH) and set a password (888888) and email. Select OK

    7. Select Initialize next to the first uninitialized Door Station (VTO) and set a user password (admin123) and email. Select OK.  

    8. Select Initialize next to the second uninitialized Door Station (VTO) and set a user password (admin123) and email. Select OK.

    9. Once all of the devices are initialized, select Next.

    10. Select Edit next to the first Indoor Monitor (VTH). Set the device type to Main and set the IP Address (192.168.1.112), Netmask (255.255.255.0) and Gateway (192.168.1.1). Select OK.

    11. Select Edit next to the second Indoor Monitor (VTH). Set the device type to Sub and set the IP Address (192.168.1.113), Netmask (255.255.255.0) and Gateway (192.168.1.1).  Select OK.

    12. Select Edit next to the first Door Station (VTO). Set the device type to Main and set the IP Address (192.168.1.108), Netmask (255.255.255.0) and Gateway (192.168.1.1). Set the Time and Date. Select OK.

    13. Select Edit next to the second Door Station (VTO). Set the device type to Sub and set the IP Address (192.168.1.111), Netmask (255.255.255.0) and Gateway (192.168.1.1).   Select OK.

    14. Once all devices have had their IP address details and device type set, select One-Key Config. The devices will now be configured. NOTE: If an error occurs during the configuration, ensured the entered details are correct.

    15. Once the devices have successfully configured, select OK.

    16. The devices will reboot, allow up to 10 minutes for them to connect. 


    Was this article helpful?

    Send feedback

    Can’t find what you’re looking for?

    Our customer care team is here for you.

    Contact Support