Cornick Help Center

    SLR-A75-4G and SLR-A75-4W Remote Control Programming

    Settings for first-generation solar units

    Default settings that should be loaded to each panel using the yellow / orange remote control.

    Note that while the trigger and timing settings here can be changed to turn on the light,  settings shown in bold are critical to the charging of the battery and should not be altered:

    BatType: Li12V

    S-Time-1: 0H

    S-C-Pow1: 10%

    S-L-Pow1: 0%      

    S-Time-2: 0H

    S-C-Pow2: 10%

    S-L-Pow2: 0%

    S-Time-3: 0H

    S-C-Pow3: 10%

    S-L-Pow3: 0%

    S-D-Time: 60S

    L-Con-V: 5V

    L-Con-DT: 0M

    LED-Cur: 0.15A (Do NOT exceed 1.1A)

    SmartPow: Yes

    0*C Chg-P: No 

    Chg-Mode: 0 

    Over-DV: 11.8

    Over-DRV: 12.2 

    Over-CV: 14.2  

    Over-CRV: 13.6

    Re-Deflt: No