Configuration property zone 1 to “Stay Profile”
Programming via keypad:
Option 1:
[*] [1479] = Installer mode
[*]
[101] = Zone Bitmap 1 Data 1 [N]
[*]
[Panic >>] until get Data 9 [N]
[*] = Change [N] to [Y]
[#] = Confirmation Zone 1 on Stay Profile 1
OR
You can enter the next sub-location (102 instead of pressing the [#] key to exit the location
Option 2:
[Stay] = press & hold until
[Stay Profile] [Profile 1]
[*] = Stay Zone
[01]
[*] = Stay Zone 1
[*] = change [N] to [Y]
[#] = Confirmation Zone 1 on Stay Profile 1