    Configure Onboard Output 1 & 2 on the WGAP864EXP1664 as CHIME.

    Learn how to program the 8 Zone Expander Module (WGAP864EXP1664) to output 1 or 2 as a DOOR CHIME.

    https://www.rhinoco.com.au/product/WGAP864EXP1664

     

    To configure Location [PRM] 1 or 2 as the Chime Output, follow these steps:

     

    1- Configure Location "PGM" 1 or 2 to Chime set

    [#] [1479] [*] = installer code

    [413] = Chime O/P  

    [*] = Sub 1 = Partition 1 - Data 00 = None Output

    [06] = Data Output 1 of the Zone Expander 1 

    [*] = Confirm PGM 1 set (On Board 1 Output)

    OR EITHER

    [07] Data Output 2 of the Zone Expander 1

    [*] = Confirm PGM 2 set (On Board 2 Output)

    [#] [#] = Back to Installer Menu

    [#] = Panel Updating process

     

    2- Configure [Zone No] activates the Chime Pulse Output for 3 seconds

    [#] [1479] [*] = installer code

    [101] = Zone Bitmap 1 (Zone 1 will be set) 

    [*] = Zone Bitmap 1 - Data 1 [N]

    Keep press [Panic>>] = Select Zone Property

    [Data 5 N] = Data Chime Zone Disable

    [*] = Changing [N] to [Y] = Enable Chime Zone set

    [#] [#] = Confirmation and Updating Panel process. 

     