3rd Generation 2-Wire
How to identify a Gen.3 INTIPRDSG
Both the box and the product label of the INTIPRDSG will have "GEN.3" written on it to identify that it is a Generation 3 INTIPRDSG. If it does not have this, it is a Generation 2 INTIPRDSG.
3rd Generation 2-Wire Wiring
Delete2nd Generation 2-Wire
2nd Generation 2-Wire Wiring
One Monitor or Door Station per 2-Wire terminal on the INTIPPOE2W (Cannot be daisy chained)
If you have more than 6 devices, connect a second INTIPPOE2W via the in/out ports.
2nd Generation 2-Wire plus IP Intercom Products Wiring
One Monitor or Door Station per 2-Wire terminal on the INTIPPOE2W (Cannot be daisy chained/cascaded)
If you have more than 6 devices, connect a second INTIPPOE2W via the in/out ports.
Connect a POE Switch to the LAN port of the INTIPPOE2W to add IP Door Stations & Monitors
INTIPRDSG & INTIPMONGW are used in the above example, but any current line Door Station or Monitor will work.
1st Generation 2-Wire
1st Generation 2-Wire Wiring
DeleteAdditional/replacement SIP Door Station or Monitor via Cat5e cable
Existing 2-Wire INTIPRDSVW2W and INTIPMONFB2W will need to be upgraded to SIP Firmware to work. INTIPRDSVW2W will have Chinese accented voice.
Connect a POE Switch to the LAN port of the Network Controller to power the new Intercom Products.
Any IP Door Station from the current range can be used in place of the INTIPRDSG
Any IP Monitor from the current range can be used in place of the INTIPMONGW
Combining Multiple Generations
Additional/replacement 2nd and 3rd Generation Door Station or Monitor via 2-Wire cable.
When connecting multiple generations of 2-wire each generation must be connected to its corresponding network controller i.e INTIPMON2W (Gen 2) must be connected to INTIPPOE2W (Gen 2) not INTIPPOE2W2 (Gen 3) or INTIPNC2W (Gen 1).
-
Generation 1:
Existing 2-Wire INTIPRDSVW2W and INTIPMONFB2W will need to be upgraded to SIP Firmware to work.
INTIPRDSVW2W will have Chinese accented voice.
-
Generation 2:
One INTIPRDSG/INTIPMON2W can be connected per port on the INTIPPOE2W
Multiple INTIPPOE2W can be connected via 2-Wire on the In/Out ports.
-
Generation 3:
All intercoms connect to the "out" port on the INTIPPOE2W2