    June 30th, 2023

    If you are unable to learn any wireless detectors with the wireless receiver, please refer to the instruction manual for the procedure on resetting the wireless receiver to its default settings.

    Information on how a wireless receiver operates.

    • [STATUS]: Yellow LED is steady on = receiver connected to WGAP864 alarm panel when powered on.
    • [RF RX]: LED indicates when the receiver received a message from a learnt detector.
    • [MODE]: Green LED indicates current operating errors and should be steady on when tamper is closed.

    Pulse error number:

    1. Wireless receiver not responding
    2. No activity on the WGAP864 serial bus
    3. No WGAP864 messages detected
    4. No messages for this peripheral detected from WGAP864
    5. Not used
    6. Expander not yet registered on the WGAP864
    7. Expander tamper violated
    8. Unsupported DIP address configured

     

    Reset to default procedure.

    1. Disconnect power on the receiver.
    2. Set all dipswitches to the on position.
    3. Reconnect power to the receiver.
    4. Wait about 10 seconds after the receiver has powered up.
    5. Disconnect power on the receiver. 
    6. And power down the alarm control panel.
    7. Set the dipswitch to the desired address then, 
    8. Reconnect power to the receiver and power up panel alarm.
    9. Wait until the [STATUS] LED remains solid for approximately 60 second.

    The wireless receiver has now been reset to the default settings and can integrate the desired address.  

     